Products

Welcome to FES Sensor Technology GmbH - a leading company in hydrogen sensor technology

Our product portfolio includes high-quality hydrogen (H2)-sensors for a safe hydrogen technology

As experts in the field of hydrogen sensor technology with many years of experience, we offer our customers innovative calibrated precision hydrogen (H2) sensors that are insensitive to siloxanes from the ambient air. They show no cross-sensitivity to hydrocarbons such as methane and ethane and can be used at a relative humidity of 0 % to 100 % and under wet vapour conditions. They are stable over the long-term and do not require calibration.

Our products

Precision Hydrogen (H2) Sensors

Precision Hydrogen Sensor with Voltage Output

Precision Hydrogen Sensor with Voltage Output signal


H2-CNI 0V-I ULTD


  • Accurate detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • Temperature range from -40 °C to +80 °C 
Product details
Precision Hydrogen Sensors with 4-20 mA Transmitter

Precision Hydrogen Sensor with 4-20 mA Transmitter


H2-CNI 4-20MA-I ULTD


  • Accurate detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • Temperature range -40 °C to +80 °C 
Product details
High precision Hydrogen Sensor

High-precision Hydrogen Sensor


H2-CNI I2C-E-ULTD


  • Accurate detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • Temperature range -40 °C to +120 °C
  • I2C bus connectivity 
Product details
H2-CNI I2C-I FWB-A

Full Digital High-precision Hydrogen Sensor

H2-CNI I2C-I FWB-A (advanced version)

H2-CNI I2C-I FWB-B (basic version FWB-B)


  • Detection of hydrogen levels up to 12 vol- % with 100 ppm resolution in air
  • Temperature range of -40 °C to +85°C
  • I2C bus connectivity


Product details
H2-TDC_I2C-I

Thermal Conductivity Hydrogen Sensor

H2-TCD I2C-I


  • Accurate detection of hydrogen levels in nitrogen or other oxygen-free atmospheres up to 100% vol-%
  • Temperature range -40 °C to +85 °C
  • I2C bus connectivity


Specification sheet Request a quote
H2-TCD 4-20MA

Thermal Conductivity Hydrogen Sensor with 4-20 mA Transmitter

H2-TCD 4-20MA


  • Accurate detection of hydrogen levels in air and nitrogen up to 15% vol-%
  • Temperature range -20 °C to +85 °C
Specification sheet Request a quote
ATEX certified housing for the hydrogen sensors

ATEX/IECEx certified housing for the hydrogen sensor

  • H2-CNI 0V-I ULTD
Product details
Test chamber for Hydrogen Sensors

Test chamber for hydrogen sensors

Product details

Sales by our partner ALDERS electronic GmbH

Arnoldstraße 19
47906 Kempen

Germany


Tel:  +49 2152 8955-230    

E-Mail: vertrieb@alders.de

The precision hydrogen (H2) sensors were developed for safe hydrogen technology. Typical applications of our hydrogen sensors are areas where hydrogen is produced, stored, transported and used. We offer hydrogen sensors for manufacturers of gas detection systems, industrial hydrogen leak detection, fuel cells‎, hydrogen laboratory applications, hydrogen vehicles and many other applications.

Our customers enjoy sophisticated consulting and can also benefit from individual requirements for specific solutions.

Of particular importance for our company are our strong partners with whom we can guarantee our customers the best product quality and service, and even better meet their individual requirements for specific solutions.

Precision Hydrogen Sensor with Voltage Output 

  • H2-CNI 0V-I ULTD
Precision Hydrogen Sensor with Voltage Output

   Features


  • Detection of hydrogen levels up to 100%
  • LEL with 100 ppm resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • No cross-sensitivity against hydrocarbons such as methane and ethane
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range from -40 to +80 °C
  • High mechanical stability
  • Linear output up to 100 % LEL
  • Available with test protocol
  • On-board instrumentation amplifier and voltage output
  • Supply voltage with reversed bias protection
Specification sheet Request a quote

Precision Hydrogen Sensor with 4-20 mA Transmitter



  • H2-CNI 4-20MA-I ULTD
Precision Hydrogen Sensor with 4-20 mA Transmitter

   Features


  • Accurate detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • Negligible sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • No cross-sensitivity against hydrocarbons such as methane and ethane
  • Fast response and recovery times
  • Negligible humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range -40 °C to +80 °C
  • Linear output up to 100 % LEL
  • 4-20 mA current-loop transmitter with reverse voltage operation and over-voltage surge protection
  • Supply voltage with reversed bias protection
Specification sheet Request a quote

High-precision Hydrogen Sensor

  • H2-CNI I2C-E-ULTD
High precision Hydrogen Sensor

   Features


  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • Extended temperature range from -40 °C to +120 °C
  • Ultralow thermal drift
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Linear output up to 100 % LEL
  • No cross-sensitivity against hydrocarbons such as methane and ethane
  • On-board digital temperature sensor and EEPROM with I2C bus connectivity 
Request a quote Specification sheet

Full Digital High-precision Hydrogen Sensors:

  • H2-CNI I2C-I FWB-A
  • H2-CNI I2C-I FWB-B


Full Digital High-precision Hydrogen Sensor

   Features


  • Detection of hydrogen levels up to 12 vol- % with 100 ppm resolution in air
  • Industrial temperature range from -40 °C to +85 °C • Ultralow thermal drift
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Linear output
  • No cross-sensitivity against hydrocarbons such as methane and ethane
  • Full Wheatstone bridge (FWB) configuration, including a digital rheostat with a nonvolatile memory for offset adjustment
  • Available as advanced version FWB-A and basic version FWB-B with adjustable precision voltage source for bridge excitation (FWB-A only), programmable gain amplification (PGA), 16-bit analog to-digital converter, on-board digital temperature sensor, and a 1K EEPROM, all of them with I2C®bus connectivit
Specification sheet Request a quote

ATEX/IECEx certified housing for H2-CNI 0V-I ULTD hydrogen sensor

ATEX certified housing for the hydrogen sensors
  • ATEX Certified II 2 G Ex db IIC T4 Gb
  • IECEx Certified Ex db IIC T4 Gb
  • Ta = -20 °C to +60 °C


According to customer requirements we offer an ATEX/IECEx certified stainless steel housing, specifically designed for our hydrogen sensor by our premium partner Dynament. The combination of the hydrogen sensor H2-CNI-I (ULTD) and the ATEX/IECEx certified sensor housing makes industrial application of hydrogen reliable and safe in hazardous areas zone 1 and zone 2.

Request a quote Specification sheet

Evaluation kit for hydrogen sensors:

  • H2-CNI 0V-I ULTD
  • H2-CNI 4-20MA-I ULTD
  • H2-CNI I2C-E-ULTD
  • H2-CNI I2C-I FWB-A
  • H2-CNI I2C-I FWB-B
  • H2-TCD I2C-I


 

evaluation kit for hydrogen sensors

The evaluation kit offers a quick start for computer control, safety monitoring as well as acquisition of analogue or digital signals. The electronics is implemented with a precise, drift-free instrumentation amplifier with programmable gain and a 16-bit analog-to-digital converter. It also contains a 1K-bit EEPROM for storing settings and three switchable LEDs (blue, orange, red) as optical signals for different H2 levels. It is operated via a 1-wire bus connection with the LabVIEW® based software SensorControl running on a personal computer.

Request a quote Evaluation kit for H2-CNI 0V Evaluation kit for H2-CNI 4-20 mA Evaluation kit for H2-CNI I2C Evaluation Kit for H2-TCD I2C-I
Share by: